Gateway for PROFINET LB8122A.1.EL

LB8122A.1.EL
  • Interface between the I/O modules and the PCS/PLC
  • Mounting in Zone 2, Class I/Div.2 or in the safe area
  • Non-volatile memory for configuration and parameter settings
  • Communication via PROFINET
  • HART communication via HART I/P

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Datasheet excerpt: Technical data of  LB8122A.1.EL

Supply
Connectionbackplane bus
Rated voltage12 V DC , only in connection with the power supplies LB9***
Nominal voltage12 V DC ,
Power dissipation4.53 W
Power consumption4.53 W
Fieldbus connection
Fieldbus typePROFINET
Ethernet Interface
Connection typeRJ-45 , via front connector
Transfer rate10BASE-T, 100BASE-TX 100 MBit/s
Station connectiondirectly to PCS or PLC or via hubs or switches
Cable typeSFTP in accordance with ISO/IEC 11801 for Cat 5e or better
Bus lengthmax. 100 m per link
AddressingDHCP, via controller (DCP) or fixed IP address
Ethernet addressIP V4 address (preset: DHCP on, changeable via display)
Supported I/O modulesLB1x01*…LB1x03*, LB1x08*, LB1x09*, LB2x01*…LB2x17*, LB3x01*…LB3x06*, LB4x01*, LB4x02*, LB4x04*…LB4x06*, LB5x01*, LB5x02*, LB5x04*…LB5x06*, LB6x01*, LB6x05*, LB6x06*, LB6x08*, LB6x10*…LB6x17*, LB7x04*
HART communicationvia PROFINET and HART I/P
PROFINET conformance classCC B
Internal bus
Connectionbackplane bus
Galvanic isolation
Ethernet/other circuitsbasic insulation according to IEC/EN 61010-1, rated insulation voltage 35 Veff or 50 V DC
RS 485 interface/other circuitsbasic insulation according to IEC/EN 61010-1, rated insulation voltage 35 Veff or 50 V DC
Insulation voltage1500 V AC acc. to IEEE 802.3u
Electrical isolation
Power supply, internal bus/other circuitsbasic insulation according to IEC/EN 61010-1, rated insulation voltage 30 V DC
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1
Conformity
Degree of protectionIEC 60529
Fieldbus standardIEEE 802.3
Environmental testEN 60068-2-14
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6
Damaging gasEN 60068-2-42
Relative humidityEN 60068-2-56
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Storage temperature-25 ... 85 °C (-13 ... 185 °F)
Relative humidity95 % non-condensing
Shock resistanceshock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Vibration resistancefrequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles
frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Mechanical specifications
Degree of protectionIP20 (module) , mounted on backplane
Connectionvia backplane
Massapprox. 150 g
Dimensions32.5 x 100 x 102 mm (1.28 x 3.9 x 4 inch)
Data for application in connection with hazardous areas
CertificateDEMKO 16 ATEX 1780 X
MarkingEx-Hexagon II 3 G Ex nA IIC T4 Gc
Directive conformity
Directive 2014/34/EUEN 60079-0:2012+A11:2013
EN 60079-15:2010

International approvals
ATEX approvalDEMKO 16 ATEX 1780 X
IECEx approvalIECEx UL 16.0141 X
Approved forEx nA IIC T4 Gc
General information
System informationThe module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity.
For use in hazardous areas (e. g. Zone 2, Zone 22 or Div. 2) the module must be installed in an appropriate enclosure.
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

Classifications

SystemClasscode
ECLASS 13.027210121
ECLASS 12.027210121
ECLASS 11.027210121
ECLASS 10.0.127210121
ECLASS 9.027210121
ECLASS 8.027210121
ECLASS 5.127210121
ETIM 9.0EC001485
ETIM 8.0EC001485
ETIM 7.0EC001485
ETIM 6.0EC001485
ETIM 5.0EC001485
UNSPSC 12.139121008

Details: LB8122A.1.EL

The PROFINET gateway is the interface between the I/O modules on the backplane and the control system.

HART communication is via PROFINET or HART I/P.

In addition to the input/output data of the I/O modules, the HART auxiliary variables can also be accessed in the process image.

Datasheet: LB8122A.1.EL

DatasheetFile TypeFile Size
Datasheet LB8122A.1.ELPDF460 KB
Datenblatt LB8122A.1.ELPDF231 KB

Documents: LB8122A.1.EL

ManualsFile TypeFile Size
CFC for STEP 7PDF1447 KB
Configuration instructions STEP 7PDF3870 KB
Configuration instructions TIA PortalPDF4041 KB
ManualPDF5367 KB
ManualPDF5915 KB
CFC für STEP 7PDF1472 KB
HandbuchPDF6011 KB
HandbuchPDF5387 KB
Konfigurationsanleitung STEP 7PDF3894 KB
Konfigurationsanleitung TIA PortalPDF4061 KB
Instruction manuals
ИнструкцииPDF152 KB
Návod k poużitíPDF146 KB
Instruktions manualPDF145 KB
Instruction manualPDF152 KB
KasutusjuhendPDF141 KB
KäyttöohjePDF141 KB
Manuel d'instructionsPDF149 KB
BetriebsanleitungPDF154 KB
Οδηγίες χρήσηςPDF156 KB
HandleidingPDF147 KB
Instruction manual / BetriebsanleitungPDF145 KB
Használati útmutatóPDF148 KB
Manuale di istruzioniPDF147 KB
Lietošanas pamācībaPDF144 KB
Instrukciju vadovasPDF145 KB
Instrukcja obsługiPDF149 KB
Manual de instruçõesPDF148 KB
Manual de utilizarePDF146 KB
Návod na poużitiePDF147 KB
Navodila za uporaboPDF144 KB
Manual de instruccionesPDF148 KB
ManualPDF143 KB
Application reports
Application Report - Communication Redundancy for Uninterrupted OperationPDF529 KB
Application Report - LB and FB Remote I/O Systems for Digitally Connecting Analog Field DevicesPDF208 KB
Application Report - Space Saving Extension for Existing PlantsPDF300 KB
Applikationsbericht - Platzsparende Erweiterung für bestehende AnlagenPDF300 KB
Applikationsbericht - Redundanz der Kommunikation für ungestörten BetriebPDF530 KB
Applikationsbericht - Remote-I/O-Systeme Typ LB und FB für digitale Anbindung analoger FeldgerätePDF208 KB
Documents
Software Product Note Remote I/O DTM / Softwareproduktschein Remote I/O DTMPDF256 KB
Release NotePDF383 KB

CAD+CAE: LB8122A.1.EL

CADFile TypeFile Size
CAD 3-D / CAD 3-DSTP1977 KB

Approvals+Certificates: LB8122A.1.EL

CertificatesFile TypeFile Size
China SITIIAS CCC Ex CertificatePDF1085 KB

Software: LB8122A.1.EL

Device DriverFile TypeFile Size
CFC Device Driver Blocks for SIMATIC PCS 7 / CFC Device Driver Blocks for SIMATIC PCS 7ZIP15869 KB
Device type managers (DTM)
DTM / DTMZIP9478 KB