Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Download the complete datasheet as a PDF:
Product Description |
---|
Combination sensor for opening and protection |
General specifications | ||
---|---|---|
Detection field | programmable , total field: 2200 mm x 1500 mm (WxD) for a mounting height of 2200 mm , measured using a horizontal test body 200 x 300 x 700 mm | |
Light source | 10 IRED 950 nm | |
Light type | modulated infrared light | |
Setting angle | -6 ... 9 ° for a mounting height of 2200 mm | |
Open time | programmable | |
Indicators/operating means | ||
Function indicator | LED red: on for object detection, flashes during teaching phase | |
Control elements | Programmble switch for switching type, open time, detection field | |
Parameterization indicator | 5 LED, red | |
Electrical specifications | ||
Operating voltage | 12 ... 31 V DC / 12 ... 30 V AC | |
No-load supply current | ≤ 100 mA | |
Power consumption | 3.5 VA | |
Input | ||
Test input | active with +UB | |
Output | ||
Switching type | light/dark on selectable programmable | |
Signal output | Relay, 1 alternator | |
Switching voltage | AC : 30 V ; DC : 32 V | |
Switching current | 300 mA | |
Switching power | 55 VA | |
Response time | ≤ 110 ms | |
Compliance with standards and directives | ||
Directive conformity | ||
EMC Directive 2004/108/EC | EN 61000-6-1 EN 61000-6-2 without EN 61000-4-5, EN 61000-4-11 , EN 61000-6-3 , EN 61000-6-4 | |
Standard conformity | ||
Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 ANSI 156,10 (as activation sensor) |
|
Approvals and certificates | ||
UL approval | UL | |
CCC approval | CCC approval / marking not required for products rated ≤36 V | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Storage temperature | -30 ... 75 °C (-22 ... 167 °F) | |
Mechanical specifications | ||
Mounting height | max. 2200 mm | |
Degree of protection | IP54 (when mounted) | |
Connection | terminal strip 8-pin 1 ... 1.5 mm2 | |
Material | ||
Housing | PC | |
Optical face | PC | |
Covering | ASA , black | |
Mass | 195 g | |
Dimensions | ||
Height | 60 mm | |
Width | 250 mm | |
Depth | 45 mm | |
Note | Safety fuse ≤ 315 mA (slow-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly. |
System | Classcode |
---|---|
ECLASS 13.0 | 27270913 |
ECLASS 12.0 | 27270913 |
ECLASS 11.0 | 27270913 |
ECLASS 10.0.1 | 27270913 |
ECLASS 9.0 | 27270913 |
ECLASS 8.0 | 27270913 |
ECLASS 5.1 | 27270903 |
ETIM 9.0 | EC002550 |
ETIM 8.0 | EC002550 |
ETIM 7.0 | EC002550 |
ETIM 6.0 | EC002550 |
ETIM 5.0 | EC001821 |
UNSPSC 12.1 | 39121528 |
We are sorry, there are no documents for your language selection. Please select another language. |
Manuals | Language | File Type | File Size |
---|---|---|---|
Instruction Manual Area scanner FLT-D / Betriebsanleitung Flächenlichttaster FLT-D | ALL | 5544 KB |
CAD | Language | File Type | File Size |
---|---|---|---|
CAD 3-D / CAD 3-D | ALL | STP | 84 KB |